Performance Science Guides for Polyester Knits
Performance in a polyester knit is expressed in measured physical quantities. Thermal and evaporative resistance, liquid moisture transport, ultraviolet protection and antimicrobial efficacy each have a standardised test method and a unit. These four guides explain what each number means, how it is measured and how to write it into a specification.
This category covers the functional properties a buyer or product developer asks of a sportswear knit: whether it insulates or releases sweat vapour, how fast it moves liquid sweat away from the skin and dries, how much ultraviolet it filters and whether it controls the bacteria that cause odour. Each value depends on its test method. The same fabric can show a different UPF under a different standard, and a drying rate from a heated plate is not the same number as one derived from weight loss. The guides therefore state the standard, the specimen state and the unit next to every value.
The four guides follow the path of heat and moisture from the skin outwards. Start with thermophysiological comfort, where Rct and Ret are measured on the sweating guarded hot plate, then read how liquid sweat wets the fabric, wicks through it and evaporates. The last two guides cover protection functions. They explain why polyester filters ultraviolet well and how antimicrobial chemistry is chosen and tested for odour control.
Decisions made in this category
| Decision | What to check |
|---|---|
| Which number shows whether a fabric breathes? | Evaporative resistance Ret in m²·Pa/W, measured on the sweating guarded hot plate to ISO 11092. The lower the Ret, the more easily sweat vapour passes Thermophysiological Comfort: Ret, Rct and the Sweating Hot Plate |
| How are warmth and breathability compared? | Thermal resistance Rct for insulation, also expressed in clo or tog, and the water-vapour permeability index imt, which weighs Rct and Ret together Thermophysiological Comfort: Ret, Rct and the Sweating Hot Plate |
| Does a wicking claim hold up? | A contact angle below 90 degrees, vertical wicking to AATCC 197 and the MMT indices of AATCC 195, above all OMMC and one-way transport R The Physics of Moisture Transport: Capillarity and MMT |
| How is a quick-dry claim stated? | The drying method together with the result. AATCC 201 and AATCC 200 are temperature-based, AATCC 199 is weight-based, and their numbers are not interchangeable The Physics of Moisture Transport: Capillarity and MMT |
| What does a UPF 50+ label guarantee? | The standard and the specimen state: new, dry and unstretched under AS/NZS 4399, or stretched, wet and washed under UV STANDARD 801. A European claim follows EN 13758-2 UPF Science: Why Polyester Shields UV Well |
| Which knit construction gives a higher UPF? | Cover factor first, then colour, weight, stretch and wetness. Tight interlock and single jersey tend to score high, high-porosity mesh tends to score low UPF Science: Why Polyester Shields UV Well |
| Which test proves an antibacterial claim? | A quantitative method such as AATCC 100 or ISO 20743, and the log reduction retained after a defined number of washes. Odour reduction itself is measured separately to ISO 17299 Antimicrobial and Odor-Control Chemistry |
Key facts
- On the ISO 11092 sweating guarded hot plate the measuring plate is held at 35 °C ± 0.1 °C. Rct is measured with the chamber at 20 °C / 65% RH, Ret at 35 °C / 40% RH. Thermophysiological Comfort: Ret, Rct and the Sweating Hot Plate
- In the widely cited scheme attributed to Hohenstein, a Ret of 0–6 m²·Pa/W rates as very good (extremely breathable) and a Ret above 30 as not breathable. Thermophysiological Comfort: Ret, Rct and the Sweating Hot Plate
- On bare polyester the water contact angle is typically 70–90 degrees. Wicking requires a contact angle below 90 degrees, so that cos(theta) is positive. The Physics of Moisture Transport: Capillarity and MMT
- With a simple hydrophilic finish, performance typically drops markedly after 30–50 wash cycles. A channelled cross-section does not change with washing, because the effect depends on shape, not chemistry. The Physics of Moisture Transport: Capillarity and MMT
- At equal weight and construction, polyester typically delivers 3–4 times the UPF of cotton. Standard polyester constructions sit at roughly UPF 15–25, and tight, dark or heavy variants easily reach 50+. UPF Science: Why Polyester Shields UV Well
- For a commercial UV-protective claim in Europe, EN 13758-2 requires a UPF above 40 and a mean UVA transmittance below 5%. UPF Science: Why Polyester Shields UV Well
- In ISO 20743 incubation typically lasts 18–24 hours. A difference of ≥2.0 log against the control counts as effective and ≥3.0 log as strong, roughly 99% and 99.9% reduction. Antimicrobial and Odor-Control Chemistry
- Zone-of-inhibition screens such as AATCC 147 and ISO 20645 are meaningful only for leaching actives and do not prove that the organism died. Antimicrobial and Odor-Control Chemistry
Reading order
- Thermophysiological Comfort: Ret, Rct and the Sweating Hot Plate — Whether a fabric “breathes” is not a marketing line but two numbers measured on a sweating guarded hot plate: thermal resistance Rct and evaporative resistance Ret. Both are measured on a sweating guarded hotplate to ISO 11092 (equivalent ASTM F1868).
- The Physics of Moisture Transport: Capillarity and MMT — Sweat’s journey from skin to environment is nothing more than contact angle, capillary pressure and an inter-layer gradient; the equation that describes it is Washburn, the instrument that measures it is the MMT. The measurement chain runs AATCC 197 (vertical wicking), AATCC 195 (MMT) and AATCC 201 (drying rate).
- UPF Science: Why Polyester Shields UV Well — UPF is not your sunscreen’s SPF — it measures how much of the sun’s damaging ultraviolet a fabric filters out, and polyester’s benzene ring is the chemical heart of the job. UPF is measured to EN 13758 and AATCC TM183.
- Antimicrobial and Odor-Control Chemistry — Fabric does not create the smell — the bacteria clinging to it do; antimicrobial chemistry breaks that chain by either binding to the fiber or releasing an active ion. Efficacy is measured quantitatively to AATCC 100 / ISO 20743 and qualitatively to AATCC 147 / ISO 20645.
Frequently asked questions
How is the UV resistance of a fabric for outdoor use verified?
There are two separate questions here. UPF measures how much a fabric protects the skin and is determined to EN 13758 and AATCC TM183. Long-term UV exposure, on the other hand, wears down protection over time through photo-oxidative degradation in polyester. How the fabric itself ages in sunlight is a separate durability test, carried out by an external laboratory.